 DATA SHEET
PS196-315: Voltage Controlled Phase Shifter 1.5-3.0 GHz
Features
1500-3000 MHz frequency band 65-100-degree phase shift range 2 dB insertion loss variation 0-12 V control voltage range Specified 33 dBm IP3 @ 1900 MHz Small footprint LGA package Lead (Pb)-free and RoHS-compliant
Connection Diagram
RF In/Out VCONTROL 10 pF
Control Voltage
RF In/Out
VCONTROL
Description
The PS196-315 is a voltage controlled phase shifter that employs a monolithic quadrature hybrid and a pair of selected silicon varactor diodes to achieve 100-degree phase shift and low insertion loss. The PS196-315 is packaged in the small outline LGA (Land Grid Array) surface mount package with the internal elements affixed to an organic BT substrate.
10 pF
NEW
Skyworks offers lead (Pb)-free, RoHS (Restriction of Hazardous Substances)-compliant packaging.
Electrical Specifications at 25 C
ZO = 50 , unless otherwise noted
Parameter Phase shift Control voltage (VCONTROL) range Control current Insertion loss in BW I.L. deviation in BW Return loss in BW IM3 IP3 PIN = 8 dBm, 1900/1905 MHz, VCONTROL = 0 V Derived from IM3 33 VCONTROL = 12 V VCONTROL = 0-12 V VCONTROL = 0-12 V 1930-1990 MHz 1930-1990 MHz 1500-3000 MHz Condition At FO, VCONTROL = 12 V Frequency 1930-1990 MHz Min. 65 0 Typ. 85 Max. 100 12 1 3.3 2 -7 -50 Unit Deg. V mA dB dB dB dBc dBm
Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com
200241 Rev. A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * September 13, 2006
1
DATA SHEET * PS196-315
Typical Performance Data
ZO = 50 , unless otherwise noted
Mag 0 V Mag 4 V Mag 8 V Mag 12 V 0 -1 Mag 1 V Mag 5 V Mag 9 V Mag 2 V Mag 6 V Mag 10 V Mag 3 V Mag 7 V Mag 11 V -7 -11 -15 Mag 0 V Mag 4 V Mag 8 V Mag 12 V Mag 1 V Mag 5 V Mag 9 V Mag 2 V Mag 6 V Mag 10 V Mag 3 V Mag 7 V Mag 11 V
Insertion Loss (dB)
Return Loss (dB)
-19 -23 -27 -31 -35 -39
-2 -3 -4 -5 1.5 1.7 1.9 2.1 2.3 2.5 2.7 2.9
-43 1.5 1.7 1.9 2.1 2.3 2.5 2.7 2.9
Frequency (GHz)
Frequency (GHz)
Magnitude S21 vs. Frequency and Control Voltage
Mag 0 V Mag 4 V Mag 8 V -7 -11 -15 Mag 12 V 270 230 190 Mag 1 V Mag 5 V Mag 9 V Mag 2 V Mag 6 V Mag 10 V Mag 3 V Mag 7 V Mag 11 V
Magnitude S22 vs. Frequency and Control Voltage
Phase 0 V Phase 3 V Phase 6 V Phase 9 V Phase 12 V Phase 1 V Phase 4 V Phase 7 V Phase 10 V Phase Phase Phase Phase 2V 5V 8V 11 V
Return Loss (dB)
-19 -23 -27 -31 -35 -39 -43 1.5 1.7 1.9 2.1 2.3 2.5 2.7 2.9
Phase (Degrees)
150 110 70 30 -10 -50 1.5 1.7 1.9 2.1 2.3 2.5 2.7 2.9
Frequency (GHz)
Magnitude S11 vs. Frequency and Control Voltage
Frequency (GHz)
Phase S21 vs. Frequency and Control Voltage
Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 2
September 13, 2006 * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * 200241 Rev. A
DATA SHEET * PS196-315
50 48 46 44 42 40 38 36 34 32 30 0 2 4 6 8 10 12
Pin Out (Bottom View)
VCONTROL VCONTROL C3 B3 GND A1 In/Out A2 GND A3 In/Out GND C2
Intermod (dBm)
C1 GND B1
Terminal No. A1 (Pin 1) A2 A3 B1 B3 C1
Terminal Name In/Out GND In/Out GND GND VCONTROL GND VCONTROL
Control Voltage (V)
3rd Order Intermod vs. Control Voltage RF1 = 1.900 GHz, RF2 = 1.905 GHz @ 8 dBm
Absolute Maximum Ratings
Characteristic RF input power Control voltage Operating temperature Storage temperature Electrostatic discharge Value 20 dBm 15 V -40 C to +85 C -65 C to +150 C HBM 1 B
C2 C3
-315
0.193 (4.90 mm) 0.004 (0.10 mm) 0.126 (3.20 mm) 0.004 (0.10 mm) 0.063 (1.60 mm) Pin 1 Indicator 0.091 (2.32 mm) 0.003 (0.091 mm) Detail A Detail B 0.030 (0.775 mm) 0.002 (0.050 mm) 0.107 (2.740 mm) 0.004 (0.100 mm)
C L
Performance is guaranteed only under the conditions listed in the specifications table and is not guaranteed under the full range(s) described by the Absolute Maximum specifications. Exceeding any of the absolute maximum/minimum specifications may result in permanent damage to the device and will void the warranty.
8X 0.004 (0.100 mm) 0.001 (0.02 mm)
CAUTION: Although this device is designed to be as robust as possible, ESD (Electrostatic Discharge) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions must be employed at all times.
C L
Detail A
0.031 (0.800 mm) 0.002 (0.050 mm) Detail C Detail B 0.031 (0.800 mm) 0.002 (0.050 mm)
Recommended Solder Reflow Profiles
Refer to the "Recommended Solder Reflow Profile" Application Note.
0.024 (0.600 mm) 0.002 (0.050 mm) Detail C Mold 0.078 (2.00 mm) 0.002 (0.05 mm) 0.013 (0.32 mm) 0.002 (0.4 mm) Seating Plane
Tape and Reel Information
Refer to the "Discrete Devices and IC Switch/Attenuators Tape and Reel Package Orientation" Application Note.
Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com
200241 Rev. A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * September 13, 2006
3
DATA SHEET * PS196-315
Copyright (c) 2002, 2003, 2004, 2005, 2006, Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. ("Skyworks") products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and "Breakthrough Simplicity" are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.
Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 4
September 13, 2006 * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * 200241 Rev. A


▲Up To Search▲   

 
Price & Availability of PS196-315

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X